Closed loop low dew point heated blower desiccant air dryer sucks ambient air, after passing through high
precision filtration and heating equipment, to heat and regenerate the desiccant. After finishing heating and
regeneration, ambient air continue to cool high temperature desiccant and cool after flowing through cooler,
which form closed loop cooling, cooling end means regeneration completion. This process doesn't lose any
compresssed dry air.
Working Condition Requirements and Technical Index
Woring pressure: 0.6~0.95MPa
Inlet air temperature:2~35℃
Ambient temperature:2℃~38℃
Pressure dew point:-40℃~-70℃
Equipment pressure drop:≤0.03MPa
Cooling water temperature:≤32℃
Cooling water pressure: 0.2-0.4MPa
Control method: PLC Programmable control
Installation method: indoor, anchor bolt installation
Selection Specification Sheet
Model |
Capacity (m³/min) |
Dimension mm |
Connection size |
Cooling water Circulation volume(T/h) |
Power supply |
Weight (kg) |
||
Length |
Width |
Height |
||||||
RGDBII-150 |
15 |
1620 |
1200 |
2370 |
DN65 |
2.1 |
380V/3ph /50Hz
Electrical grade IP54 |
1150 |
RGDBII-220 |
20 |
1760 |
1350 |
2550 |
DN80 |
2.9 |
1380 |
|
RGDBII-270 |
27 |
1760 |
1350 |
2650 |
DN80 |
3.9 |
1680 |
|
RGDBII-320 |
32 |
1820 |
1370 |
2550 |
DN80 |
4.6 |
1850 |
|
RGDBII-370 |
37 |
1820 |
1370 |
2700 |
DN80 |
5.3 |
2200 |
|
RGDBII-450 |
45 |
2120 |
1520 |
2700 |
DN100 |
6.4 |
3330 |
|
RGDBII-550 |
55 |
2320 |
1620 |
2900 |
DN100 |
7.8 |
4000 |
|
RGDBII-650 |
65 |
2800 |
1800 |
2800 |
DN125 |
9.2 |
4800 |
|
RGDBII-850 |
85 |
3140 |
1970 |
2860 |
DN125 |
12 |
5750 |
|
RGDBII-1000 |
100 |
3330 |
2030 |
3100 |
DN125 |
14 |
7300 |
|
RGDBII-1250 |
125 |
3500 |
2150 |
3200 |
DN125 |
17.5 |
8300 |
|
RGDBII-1500 |
150 |
4160 |
2650 |
3260 |
DN150 |
21 |
11000 |
|
RGDBII-1800 |
180 |
4300 |
2750 |
3300 |
DN200 |
25.2 |
13500 |
|
RGDBII-2000 |
200 |
4800 |
2900 |
3450 |
DN200 |
28 |
15000 |
|
RGDBII-2500 |
250 |
5000 |
3000 |
3500 |
DN250 |
35 |
20000 |
|
RGDBII-3000 |
300 |
5000 |
3100 |
3800 |
DN250 |
42 |
24000 |
|
RGDBII-3500 |
350 |
6000 |
3600 |
3800 |
DN250 |
49 |
26000 |
Note: DN is flange connection, flange standard HG/T20592-2009
If the model, specification and color change, please be subject to actual product, there will be not further notice
Over 350 cubic meters or other special standards can be customized