Heated blower desiccant air dryer employs the blower to suck ambient air, after heating the air, thenregenerates the desiccant,
which avoid the air loss during heating regeneration process. It achieves the most reliable and highest energy-saving effect of the dryer.
Working Condition Requirements and Technical Index
Working pressure:0.6~0.95MPa
Inlet air temperature:2~35℃
Ambient temperature:2℃~38℃
Pressure dew point:-20℃~-40℃
Equipment pressure drop:≤0.03MPa
Regenerative air loss:1.5%
Control method:PLC Programmable control
Installation method: indoor, anchor bolt installation
Temperature and Pressure Correction System
Inlet Temperature |
Inlet Pressure |
|||||
5 |
6 |
7 |
8 |
9 |
10 |
|
30 |
0.86 |
1.00 |
1.15 |
1.18 |
1.25 |
1.30 |
35 |
0.75 |
0.87 |
1.00 |
1.12 |
1.15 |
1.20 |
40 |
0.45 |
0.58 |
0.71 |
0.82 |
0.92 |
1.03 |
45 |
0.32 |
0.42 |
0.53 |
0.62 |
0.74 |
0.89 |
Selection Specification Sheet
Model |
Capacity (m³/min) |
Dimension mm |
Connection Size |
Installation Power |
Power Supply |
Weight (kg) |
||
Length |
Width |
Height |
||||||
RGDBI-150 |
15 |
1620 |
1200 |
2370 |
DN65 |
16.5 |
380V/3ph /50Hz
Electrical grade IP54 |
1000 |
RGDBI-220 |
22 |
1760 |
1350 |
2550 |
DN80 |
19.1 |
1200 |
|
RGDBI-270 |
27 |
1760 |
1350 |
2650 |
DN80 |
27 |
1450 |
|
RGDBI-320 |
32 |
1820 |
1370 |
2550 |
DN80 |
27 |
1600 |
|
RGDBI-370 |
37 |
1820 |
1370 |
2700 |
DN80 |
32 |
1900 |
|
RGDBI-450 |
45 |
2120 |
1520 |
2700 |
DN100 |
39 |
2900 |
|
RGDBI-550 |
55 |
2320 |
1620 |
2900 |
DN100 |
45 |
3500 |
|
RGDBI-650 |
65 |
2800 |
1830 |
2850 |
DN125 |
54 |
4200 |
|
RGDBI-850 |
85 |
3140 |
1970 |
2860 |
DN125 |
83 |
5000 |
|
RGDBI-1000 |
100 |
3330 |
2030 |
3100 |
DN125 |
89 |
6400 |
|
RGDBI-1250 |
125 |
3500 |
2150 |
3200 |
DN125 |
120 |
7200 |
|
RGDBI-1500 |
150 |
4160 |
2650 |
3260 |
DN150 |
148 |
9200 |
|
RGDBI-1800 |
180 |
4300 |
2750 |
3300 |
DN200 |
160 |
12500 |
|
RGDBI-2000 |
200 |
4800 |
2900 |
3450 |
DN200 |
175 |
15000 |
|
RGDBI-2500 |
250 |
5000 |
3000 |
3500 |
DN250 |
230 |
18000 |
|
RGDBI-3000 |
300 |
5500 |
3200 |
3600 |
DN250 |
270 |
22000 |
|
RGDBI-3500 |
350 |
6000 |
3600 |
3600 |
DN250 |
336 |
24000 |
Note:DN is flange connection ,flange standard HG/T20592-2009
Standard flow rate is the capacity based on 20℃/0.1MPa,working pressure 0.7MPa and ambient temperature.
The biggest inlet condition of blower is 35℃/45%30℃/60%, Over 350 cubic meters or other special standards can be customized